Effect of Inverse I : E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (2024)

Skip Nav Destination

Article navigation

Volume 88, Issue 1

January 1998

  • Previous Issue
  • Next Issue
  • Previous Article
  • Next Article
  • Materials and Methods

  • Results

  • Discussion

  • REFERENCES

Clinical Science| January 1998

Elizabeth Zavala, MD;

Elizabeth Zavala, MD

Search for other works by this author on:

This Site

Miguel Ferrer, MD;

Miguel Ferrer, MD

Search for other works by this author on:

This Site

Guido Polese, MD;

Guido Polese, MD

Search for other works by this author on:

This Site

JoanRamon Masclans, MD;

JoanRamon Masclans, MD

Search for other works by this author on:

This Site

Merce Planas, MD;

Merce Planas, MD

Search for other works by this author on:

This Site

Joseph Milic-Emili, MD;

Joseph Milic-Emili, MD

Search for other works by this author on:

This Site

Robert Rodriguez-Roisin, MD;

Robert Rodriguez-Roisin, MD

Search for other works by this author on:

This Site

Andrea Rossi, MD

Andrea Rossi, MD

Search for other works by this author on:

This Site

Author and Article Information

(Zavala) Chief of Section, Surgical Intensive Care Unit.

(Ferrer, Polese) Staff, Pneumology Unit.

(Masclans) Staff, Intensive Care Unit.

(Planas) Chief of Section, Intensive Care Unit.

(Milic-Emili) Professor of Physiology and Medicine.

(Rodriguez-Roisin) Professor of Medicine; Chief, Lung Unit.

(Roca) Chief of Section, Pneumology.

(Rossi) Chief of Lung Unit.

Anesthesiology January 1998, Vol. 88, 35–42.

  • Split-Screen
  • Views Icon Views
    • Article contents
    • Figures & tables
    • Video
    • Audio
    • Supplementary Data
    • Peer Review
  • Open the PDF for in another window
  • Cite Icon Cite

  • Search Site

Citation

Elizabeth Zavala, Miguel Ferrer, Guido Polese, JoanRamon Masclans, Merce Planas, Joseph Milic-Emili, Robert Rodriguez-Roisin, Josep Roca, Andrea Rossi; Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome. Anesthesiology 1998; 88:35–42 doi: https://doi.org/10.1097/00000542-199801000-00008

Download citation file:

  • Ris (Zotero)
  • Reference Manager
  • EasyBib
  • Bookends
  • Mendeley
  • Papers
  • EndNote
  • RefWorks
  • BibTex
toolbar search

Search Dropdown Menu

Advanced Search

Background

It is not known whether inverse I:E ratio ventilation (IRV) offers any real benefit over conventional mechanical ventilation with positive end-expiratory pressure (CMV-PEEP) at similar levels of end-expiratory pressure.

Methods

The effects of volume-controlled and pressure-controlled IRV (VC-IRV and PC-IRV, respectively) on VA/Q inequality were compared with those of CMV-PEEP at a similar level of end-expiratory pressure and with CMV without PEEP (CMV) in eight patients in the early stages of acute respiratory distress syndrome (ARDS). Respiratory blood gases, inert gases, lung mechanics, and hemodynamics were measured 30 min after the onset of each ventilatory mode.

Results

Recruitment of nonventilated, poorly ventilated (or both) but well-perfused alveoli increased the partial pressure of oxygen (PaO2) during CMV-PEEP (+13 mmHg) and IRV-VC (+10 mmHg; P < 0.05) compared with CMV. In contrast, PC-IRV did not affect PaO2 but caused a decrease in PaCO2 (-7 mmHg; P < 0.05). The latter was due to a concomitant decrease in dead space (P < 0.01) and shift to the right of VA/Q distributions. During PC-IRV, the increase in the mean of blood flow distribution (mean Q; P < 0.01) without a change in the dispersion (log SD Q) did not result in an increase in PaO2, probably because it reflected redistribution of blood flow within well-ventilated areas.

Conclusions

Short-term PC-IRV improved carbon dioxide clearance, but the lung became less efficient as an oxygen exchanger. Furthermore, based on mean airway and plateau pressures, the risk of barotrauma was not reduced with this type of ventilation.

Topics:

cytomegalovirus, hemodynamics, positive end-expiratory pressure, pulmonary gas exchange, respiration, respiratory distress syndrome, adult, noble gases, respiratory mechanics, lung, periacetabular osteotomy

Although mechanical ventilation is not a curative therapy but rather a way to provide time for the lungs to recover from acute injury, the adequate setting of the ventilator is a fundamental aspect of appropriate patient management. [1,2]In the past 10 yr, the inverse I:E ratio mechanical ventilation (IRV) has been used increasingly as an alternative ventilatory technique in patients with acute respiratory distress syndrome (ARDS)[3]to improve oxygenation at lower than conventional peak airway pressure (peak Paw).

Three potential mechanisms have been invoked to explain the increase in the partial pressure of oxygen (PaO2) with IRV [3–6]:(1) higher mean airway pressure (mean Paw);(2) intrinsic positive end-expiratory pressure (PEEPi) elicited by the short expiratory time; and (3) improved intrapulmonary distribution of the inspired gas due to the lower mean inspiratory flow. However, based on the discrepant results obtained in several clinical studies, [5,7–14]it is not yet evident whether IRV offers any real, even short-term, benefit over conventional controlled mechanical ventilation (CMV) with PEEP. This is particularly true when comparison is made at similar levels of end-expiratory pressure [6,13]and volume. [11,14]Given these discrepant results and because improvement of oxygenation is the major aim of IRV, a better understanding of the mechanisms underlying the effects of IRV on pulmonary gas exchange is warranted. Accordingly, we investigated the effect on gas exchange of four ventilator settings:(1) volume-controlled mechanical ventilation without PEEP (CMV);(2) volume-controlled mechanical ventilation with PEEP (CMV-PEEP);(3) volume-controlled inverse I:E ratio ventilation (VC-IRV); and (4) pressure-controlled inverse I:E ratio ventilation (PC-IRV). The comparison was made at the same level of total PEEP while keeping tidal volume, respiratory rate, and inspiratory oxygen fraction (FIO2) unchanged.

Materials and Methods

Population

The study was approved by the Ethics Committee of the Hospital Clinic, and written informed consent was obtained from each patient's next of kin. Eight mechanically ventilated patients were studied early in the course of ARDS; that is, within 48 h from onset of acute respiratory failure. The inclusion criteria, which were in keeping with the International Consensus Conference, [2]included presence of severe hypoxemia (PaO2/FIO2ratio < 200 mmHg) and bilateral pulmonary infiltrates. None of the patients had preexisting chronic respiratory disease, left-ventricular failure defined by a pulmonary artery occlusion pressure (PAOP) > 15 mmHg, or the presence of thoracic drains or rib cage instability. Severity of ARDS expressed as lung injury score [15]was 2.6 +/- 0.4 (SD). All patients were orotracheally intubated with a Portex cuffed endotracheal tube and were mechanically ventilated with a Siemens 900C Servo Ventilator (Siemens-Elema BA, Solna, Sweden) using the volume-controlled mode with constant inspiratory flow (V with dot1) and PEEP before the study. Table 1shows patients characteristics.

Table 1. Clinical Data of Patients

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (2)

View large

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (3)

View Large

Hemodynamics

The electric activity of the heart was monitored continuously. An 18-gauge plastic cannula was inserted into the radial artery for monitoring systemic blood pressure and for arterial blood sampling. A 7-French triple-lumen thermodilution, balloon-tipped pulmonary artery catheter (Edwards; Baxter Healthcare, Irvine, CA) was inserted percutaneously and progressed into the pulmonary artery to measure pulmonary artery pressure, pulmonary artery occlusion, and right atrial pressure (model 56S; Hewlett-Packard, Andover, MA). Average measurements of three consecutive breaths were taken at end expiration. Thermodilution cardiac output (Q with dotT) was measured by injecting 10 ml cold 0.9% saline solution into the proximal end of the pulmonary artery catheter. Reported Q with dotTvalues are the means of four consecutive measurements. Pulmonary vascular resistance was calculated according to the standard formula.

Respiratory Mechanics

Airway pressure was measured with a differential pressure transducer (model 143PCO3D; Honeywell, Freeport, IL) through a side port at the proximal end of the endotracheal tube. Flow (V with dot) was measured with a Fleisch no. 1 heated pneumotachograph (Metabo, Lausanne, Switzerland) connected to a differential pressure transducer (model 304A; Hewlett-Packard, Palo Alto, CA) and inserted between the endotracheal tube and the Y connection of the ventilator. Tidal volume was calculated by mathematical integration of the flow signal. Inspiratory time (TI), expiratory time (TE), total breathing cycle duration (TTOT), respiratory frequency (f), and minute ventilation (V with dotE) were also calculated. Peak Paw and plateau pressure (Pplat) during brief end-expiratory and end-inspiratory airway occlusion were recorded. [16,18]At the end of a tidal expiration, the expiratory line of the ventilator was occluded using the end-expiratory hold button of the ventilator for direct measurement of PEEPias the difference between the plateau in mean Paw during the occlusion (approximately 1 s) and the mean Paw level before interruption. Without PEEP set by the ventilator, the plateau in mean Paw during the occlusion, compared with atmospheric pressure, reflects PEEPi(i.e., the end-expiratory elastic recoil pressure). When PEEP has been set by the ventilator, the plateau in mean Paw during the end-expiratory occlusion represents the total PEEP (PEEPt), whereas the difference between the plateau and the preinterruption level provides PEEPi, according to the formula (PEEPt= PEEP + PEEP sub i). After the end-expiratory plateau was observed, the occlusion was released for mechanical lung inflation. Then the end-inspiratory occlusion was performed using the end-inspiratory hold button of the ventilator. Immediately after, a rapid decrease in mean Paw was observed, followed by a gradual decrease to a plateau (Pplat), reflecting the end-inspiratory elastic recoil at the end-inflation lung volume. As soon as such a plateau was achieved (approximately 2–3 s), the occlusion was released. These maneuvers (end-expiratory and end-inspiratory airway occlusion) were repeated three to five times, leaving seven regular mechanical ventilatory cycles in between.

Respiratory Gases

Inspired oxygen fraction (FIO2) and mixed expired oxygen (FEO2) and carbon dioxide (FICO2) fractions were measured using mass spectrometry (Multigas Monitor MS-2; BOC-Medishield, London, UK). A small arterial catheter, indwelling in the radial artery for clinical purposes under local anesthesia, was used to sample arterial blood with a heparin-prepared syringe to measure arterial oxygen pressure (PO2), carbon dioxide pressure (PCO2, and pH by standard electrode technique (IL-306, Instrumentation Laboratories, Milano, Italy). Mixed venous blood was sampled from the distal lumen of the Swan-Ganz catheter to measure mixed venous PO2. Venous admixture (Q with dot/Q with dotT), oxygen delivery (D with dot O sub 2), and oxygen consumption (V with dot O2) were calculated according to standard formulas.

Distribution of Ventilation-Perfusion Ratios

The multiple inert gas elimination technique is based on the simultaneous elimination of trace concentrations of six inert gases (sulfur hexafluoride, ethane, cyclopropane, enflurane, ether, and acetone) infused, in a saline solution, into a peripheral vein of the forearm. [17]General features of the setup of the multiple inert gas elimination technique in our laboratory have been reported elsewhere. [17,18]* Briefly, after approximately 45 min of infusion of the solution of the six inert gases at a rate of 3 ml/min, arterial, mixed venous (8 ml each), and mixed expired samples were simultaneously obtained in duplicate. Mixed expired gases were collected through a 1-l inner volume metallic heated box inserted in the expiratory line of the ventilator.* Duplicate samples of arterial, mixed venous blood, and mixed expired gases were processed separately. Results are reported as mean values of duplicate measurements. Shunt was defined as the fraction of blood flow to unventilated alveoli (% Q with dotTto V with dot sub A /Q with dot ratio < 0.005). Low V with dotA/Q with dot and high V with dotA/Q with dot were defined as the percentage of perfusion to poorly ventilated units (% Q with dotTto V with dot sub A /Q with dot ratio between 0.005 and 0.1) and the percentage of alveolar ventilation to poorly perfused units (% V with dotAto V with dotA/Q with dot ratio between 10 and 100), respectively. Dead space was defined as the percentage of alveolar ventilation to unperfused units (% V with dotAto V with dotA/Q with dot ratio > 100). The position (first moment) of the perfusion (mean Q with bar) and ventilation (mean V with bar) was defined as the mean V with dotA/Q with dot ratio of each distribution, and their dispersion (second moment) as the standard deviation of perfusion (log SD Q) and ventilation (log SD V) distributions on a logarithmic scale. The residual sum of squares is a quantitative estimation of the overall experimental error in the assessment of V with dotA/Q with dot distributions. [17]

Study Design

Patients were studied in the semirecumbent position in a stable clinical condition. They were sedated during the study with continuous intravenous infusion of midazolam (Dormicum; Roche SA, Madrid, Spain). Patients were paralyzed with pancuronium bromide (Pavulon; Organon-Hermes SA, Sant Boi de Llobregat, Spain) to avoid muscular activity during the measurements. The patients were studied under four different ventilatory modalities. The V with dotE, VT, f, and FIO2, which had been prescribed by the attending physicians, were kept unaltered throughout the procedure. In addition, the standard medical treatment (antibiotics, vasoactive drugs, diuretics, and so on) was not changed throughout the procedure, except for additional sedation and paralysis when needed. The following changes were made in the ventilator settings to implement the targeted ventilator modalities:(1) PEEP, which was always present before the study (Table 1), was removed to implement the controlled mechanical ventilation mode (CMV) without PEEP;(2) the level of PEEP was set at 8 cmH2O in all patients to obtain the CMV-PEEP mode;(3) without any PEEP set by the ventilator, the Tiwas increased progressively while leaving TTOTunaltered but shortening TEuntil a level of PEEPiof about 8 cmH2O was achieved during volume-cycled ventilation with constant flow (this mode was called VC-IRV); and (4) with a setting similar to VC-IRV, the inspiratory support mode was changed to pressure control (PC-IRV) with which a PEEPiof about 8 cmH2O was generated. No end-inspiratory pause was used. After establishing the ventilatory parameters needed to fulfill all required protocols, the order of the modalities was randomly assigned to each patient. The arterial oxygen saturation was monitored during the study by pulse oximetry (model M1092-A; Hewlett Packard, Savonmo, Italy) and maintained above 96%. Patients were studied under steady-state conditions, which in all instances had been established after 30 min of ventilation with each ventilatory mode, as judged by the monitoring of ventilatory and hemodynamic variables, as well as mixed expiratory respiratory gases. After 30 min at each ventilating mode, measurements were made in the following order of (1) multiple inert gas elimination technique and expired, arterial, and mixed venous blood gases;(2) pulmonary and systemic hemodynamics; and (3) respiratory mechanics.

Statistical Analysis

Results are presented as means +/- SD, unless otherwise stated. A two-way analysis of variance for repeated measurements and Fisher contrast analyses were used for comparison among ventilatory modes. Student's paired t test was used when required to compare between two groups of data. Probability values < 0.05 were accepted as significant.

Results

Ventilatory Pattern and Respiratory Mechanics

By design (Table 2), minute ventilation, tidal volume, and ventilator frequency were kept constant throughout the study. Accordingly, Tiand TEwere significantly longer and shorter, respectively, during IRV. A small PEEPiwas found during CMV without PEEP set by the ventilator, as previously reported in patients with ARDS. [16]Peak Paw was lower during IRV than CMV-PEEP, whereas Pplatwas not different among the three modalities (CMV-PEEP, VC-IRV, and PC-IRV). Mean mean Paw was higher during IRV than CMV-PEEP, with the highest value occurring during PC-IRV. Static elastance decreased during PEEP and IRV.

Table 2. Ventilatory Pattern and Respiratory Mechanics

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (4)

View large

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (5)

View Large

Blood Gases and Hemodynamics

(Table 3) shows the blood gas and hemodynamic measurements. Arterial PO2improved with PEEP (+13 mmHg, on average) and with VC-IRV (+10 mmHg, on average). In contrast, with PC-IRV, PaO2did not change compared with CMV. Arterial PaCO2and pH were lower and higher, respectively, with IRV (particularly with PC-IRV) than with CMV. Systemic hemodynamics and oxygen delivery were not influenced by the different ventilatory modalities. Only pulmonary capillary occlusion pressure increased with PEEP and IRV.

Table 3. Pulmonary and Systemic Hemodynamics and Respiratory Blood Gas Data

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (6)

View large

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (7)

Inert Gas Exchange

(Table 4) shows the inert gas data under the four different ventilatory conditions. As expected, perfusion to unventilated V with dotA/Q with dot units (shunt) decreased significantly with CMV-PEEP, which essentially explains the observed increase in PaO2with CMV-PEEP compared with CMV. A representative pattern of the V with dotA/Q with dot inequality with the four ventilator settings used in this study is shown in Figure 1. During CMV, V with dotA/Q with dot distributions showed the well-known V with dotA/Q with dot pattern previously reported in ARDS [19]: unimodal ventilation and perfusion distributions associated with a large intrapulmonary shunt and a small increase in dead space.

Table 4. Inert Gas Exchange Data

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (8)

View large

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (9)

View Large

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (10)

View largeDownload slide

Figure 1. Ventilation-perfusion (V with dotA/Q with dot) distributions with the four ventilatory modes in a representative patient with acute respiratory distress syndrome.

Effect of Inverse I: E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (11)

View largeDownload slide

Figure 1. Ventilation-perfusion (V with dotA/Q with dot) distributions with the four ventilatory modes in a representative patient with acute respiratory distress syndrome.

Close modal

During VC-IRV, inert gas shunt and V with dotA/Q with dot distributions did not show significant changes compared with CMV-PEEP. During PC-IRV, however, the percentage of shunt was higher than during CMV-PEEP. Compared with CMV-PEEP and VC-IRV, the inert gas results during PC-IRV suggest a redistribution of blood flow to lung units with a V with dotA/Q with dot ratio higher than 1. Mean Q with bar increased in both CMV-PEEP and VC-IRV. Further, mean V with bar was higher in PC-IRV than in VC-IRV. As indicated in Table 4, the dead space decreased during PC-IRV.

The arterial PO2predicted from the inert gas data was similar to the PaO2measured from arterial blood (the difference between predicted and measured PaO2was 2.7 +/- 13.1 mmHg; P = 0.3). Quality control of inert gas measurements as assessed by the residual sum of squares showed acceptable results. Mean +/- SD value for residual sum of squares was 2.8 +/- 1.7 (the upper limit for residual sum of squares is generally set at 10). Agreement between the cardiac output calculated from the inert gas data (7.8 +/- 3.6 l/min) and that obtained by thermodilution (8.0 +/- 3.2 l/min; r = 0.96) provided further support for the accuracy of the inert gas measurements.

Discussion

We found that IRV in VC-IRV and PC-IRV modalities does not provide any short-term improvement of gas exchange relative to CMV with PEEP, when the comparison is made at similar levels of total end-expiratory pressure while tidal volume, respiratory rate, and FIO sub 2 were kept constant. Application of PEEP of 8 cmH2O (CMV-PEEP) significantly increased PaO2(about 13 mmHg) compared with CMV alone, mainly because of a significant decrease (7%) in intrapulmonary shunt. Because cardiac output did not change significantly (Table 3), the decrease in shunt should be attributed to recruitment of previously nonventilated units, [19]as suggested by static elastance.

During PC-IRV, the increase in mean Q with bar (Table 4) reflects redistribution of blood flow within regions of normal V with dotA/Q with dot ratio, which may not improve the oxygen exchange capability of the lungs with large shunt. Further, the percentage of shunt during PC-IRV was similar to that in CMV, which explains why PaO sub 2 was less with PC-IRV than with VC-IRV and CMV-PEEP. The significant decrease in PaCO2during PC-IRV in our study was due to (1) the shift to the right of V with dotA/Q with dot distributions and (2) a significant decrease in the inert gas dead space with the prolonged inspiratory duration. This is corresponds with the results of previous studies [11,13]in which a decrease in physiologic dead space with PC-IRV was also found. Overall, the gas exchange results in the present study suggest that during PC-IRV, the lungs, although not more efficient as an oxygen exchanger, become more efficient in clearing carbon dioxide. Whether the decrease in PaCO2with PC-IRV is clinically relevant remains to be established.

Our results are in keeping with those of previous studies [13,14]that have shown that PC-IRV did not improve PaO2compared with traditional CMV with PEEP, when the comparison is made at equal levels of PEEP, while keeping the other ventilator variables constant. Lessard et al. [14]also observed a lower PaO2with PC-IRV compared with conventional ventilation with PEEP. Similarly, these authors did not find a significant change in cardiac output with PC-IRV. Mercat et al. [13]and Lessard et al. [14]used higher levels of PEEPtthan in the present study, namely from 11 to 14 cmH2O. This, however, indicates that our negative results with IRV cannot be attributed to insufficient PEEPt. [6]We cannot compare our results obtained with inverse I:E ratio ventilation with those of most previous studies because of lack of information on the level of PEEPtused due to uncontrolled modifications in the ventilator settings after implementation of IRV. Clearly, we cannot exclude the possibility that different effects of PC-IRV may be found in more severely hypoxemic patients who cannot be adequately ventilated with the conventional modes. A potential critique of the present and previous well-controlled studies [13,14]pertains to the relatively short duration of the different ventilation modes. Indeed, although it is evident that PC-IRV does not provide any short-term benefit over traditional CMV with PEEP, it cannot be excluded that a longer period of its application may lead to a different result. However, it has been shown that most of the PaO sub 2 improvement occurs within minutes of the increase in the end-expiratory pressure, [20]although in some patients with ARDS PaO sub 2 might continue to improve for hours after implementation of IRV. Such time-dependent effect, however, was not detected in a controlled study in which PC-IRV was applied for 24 h. [5]In contrast to the data reported by Sydow et al. [21]it has been suggested that oxygenation could improve after 8 h with VC-IRV. However, that study dealt mainly with mean Paw release and cannot be considered conclusive in terms of the effects of IRV on pulmonary gas exchange. We believe that this question, as well as the related question regarding the cardiovascular effects of prolonged application of IRV, should be answered before planning large-scale clinical studies with IRV.

The inspiratory flow rate and, consequently, peak Paw were lower in IRV than in CMV-PEEP. The lack of differences in Pplatbetween these ventilatory modalities (IRV and CMV-PEEP), despite the differences in peak Paw, is explained by the resistive pressure decrease, which represents the difference between peak Paw and Pplat, which essentially occurs within the endotracheal tube. [22]Consequently, the lower peak cycling pressure during IRV is likely to be irrelevant in terms of the risk for barotrauma. In our patients, the greater mean mean Paw did not improve PaO2, supporting the conclusion by East et al. [5]that arterial oxygenation may be more closely related to PEEPtthan mean mean Paw. Comparison with other studies [4]is difficult because PEEPtwas not reported.

In conclusion, we explored the mechanisms underlying the changes in pulmonary oxygenation with IRV. We did not find any short-term benefit for IRV, in terms of PaO2, compared with the conventional CMV with equivalent levels of PEEP. Although our results do not rule out the possibility that patients with severe hypoxemia may benefit by longer periods of IRV administration, such a therapy should be limited to selected patients and under the supervision of skilled and experienced medical staff. [5,12]Because large controlled, well-designed, randomized, prospective clinical trials in critically ill patients are difficult to perform, there is insufficient evidence to warrant the implementation of such large clinical studies with IRV in patients with ARDS, whereas delayed beneficial effects of IRV might deserve further investigation.

*Zavala E, Burgos F, Diaz O, Ferrer M, Roca J, Barbera JA, Wagner PD, Rodriguez-Roisin R: Assessment of pulmonary gas exchange in mechanically ventilated patients [Abstract]. Intensive Care Med 1995; 22:S405.

REFERENCES

1.

slu*tsky A: Consensus conference on mechanical ventilation. Part I. Intensive Care Med 1994; 20:64-79.

2.

Bernard G, Artigas A, Brighman K, Carlet J, Falke K, Hudson L, Lamy M, Legall J, Morris A, Spragg R: The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination. Am J Respir Crit Care Med 1994; 149:818-24.

3.

Marcy TW, Marini JJ: Inverse ratio ventilation in ARDS. Rationale and implementation. Chest 1991; 100:494-504.

4.

Gattinoni L, Marcolin R, Caspani M, Fumagali R, Mascheroni D, Pesenti A: Constant mean airway pressure with different patterns of positive pressure breathing during the adult respiratory distress syndrome. Bull Eur Physiopathol Respir 1985; 21:275-9.

5.

East T, Bohm S, Wallace J, Clemmer T, Weaver L, Orme J, Morris A: A successful computerized protocol for clinical management of pressure control inverse ratio ventilation in ARDS patients. Chest 1992; 101:697-710.

6.

Brandolese R, Broseghini C, Polese G, Bernasconi M, Brandi G, Milic-Emili J, Rossi A: Effects of intrinsic PEEP on pulmonary gas exchange in mechanically-ventilated patients. Eur Respir J 1992; 6:358-63.

7.

Gurevitch M, Van Dyke J, Young E, Jackson K: Improved oxygenation and lower peak airway pressure in severe adult respiratory distress syndrome. Treatment with inverse ratio ventilation. Chest 1986; 89:211-3.

8.

Tharratt R, Allen R, Albertson T: Pressure controlled inverse ratio ventilation in severe adult respiratory failure. Chest 1988; 94:755-62.

9.

Lain D, DiBenedetto R, Morris S, Van Nguyen A, Saulters R, Causey D: Pressure control inverse ratio ventilation as a method to reduce peak inspiratory pressure and provide adequate ventilation and oxygenation. Chest 1989; 95:1081-8.

10.

Abraham E, Yoshihara G: Cardiorespiratory effects of pressure controlled inverse ratio ventilation in severe respiratory failure. Chest 1989; 96:1356-9.

11.

Poelaert J, Vogelaers D, Colardyn F: Evaluation of the hemodynamic and respiratory effects of inverse ratio ventilation with a right ventricular ejection fraction catheter. Chest 1991; 99:1444-50.

12.

Chan K, Abraham E: Effects of inverse ratio ventilation on cardiorespiratory parameters in severe respiratory failure. Chest 1992; 102:1556-61.

13.

Mercat A, Graini L, Teboul J, Lenique F, Richard C: Cardiorespiratory effects of pressure-controlled ventilation with and without inverse ratio in the adult respiratory distress syndrome. Chest 1993; 104:871-5.

14.

Lessard M, Guerot E, Lorino H, Lemaire F, Brochard L: Effects of pressure-controlled with different I:E ratios versus volume-controled ventilation on respiratory mechanics, gas exchange, and hemodynamics in patients with adult respiratory distress syndrome. Anesthesiology 1994; 80:983-91.

15.

Murray JF, Matthay MA, Luce JM, Flick MR: An expanded definition of the adult respiratory distress syndrome. Am Rev Respir Dis 1988; 138:720-3.

16.

Rossi A, Polese G, Brandi G, Conti G: Intrinsic positive end-expiratory pressure (PEEPi). Intensive Care Med 1995; 21:522-36.

17.

Roca J, Wagner PD: Contribution of multiple inert gas elimination technique to pulmonary medicine. 1: Principles and information content of the multiple inert gas elimination technique. Thorax 1993; 49:815-24.

18.

Rossi A, Santos C, Roca J, Torres A, Felez MA, Rodriguez-Roisin R: Effects of PEEP on VA/Q mismatching in ventilated patients with chronic airflow obstruction. Am J Respir Crit Care Med 1994; 149:1077-84.

19.

Dantzker DR, Brook L, DeHart P, Lynch J, Weg J: Ventilation-perfusion distribution in the adult respiratory distress syndrome. Am Rev Respir Dis 1979; 120:1039-52.

20.

Katz J, Ozanne G, Zinn S, Fairley H: Time course and mechanisms of lung-volume increase with PEEP in acute pulmonary failure. Anesthesiology 1981; 54:9-16.

21.

Sydow M, Burchardi H, Ephraim E, Zielmann S, Crozier T: Long-term effects of two different ventilatory modes on oxygenation in acute lung injury. Am J Respir Crit Care Med 1994; 149:1550-6.

22.

Pesenti A, Pelosi P, Rossi A: The effects of positive-end expiratory pressure in patients with the adult respiratory distress syndrome and in normal anesthetized subjects. Am Rev Respir Dis 1991; 144:101-7.

Copyright 1998 by the American Society of Anesthesiologists, Inc.

3,705 Views

37 Web of Science

39 Crossref

View Metrics

×

Citing articles via

Google Scholar

Most Viewed

2022 American Society of Anesthesiologists Practice Guidelines for Management of the Difficult Airway

Practice Guidelines for Preoperative Fasting and the Use of Pharmacologic Agents to Reduce the Risk of Pulmonary Aspiration: Application to Healthy Patients Undergoing Elective Procedures: An Updated Report by the American Society of Anesthesiologists Task Force on Preoperative Fasting and the Use of Pharmacologic Agents to Reduce the Risk of Pulmonary Aspiration

Practice Guidelines for Moderate Procedural Sedation and Analgesia 2018: A Report by the American Society of Anesthesiologists Task Force on Moderate Procedural Sedation and Analgesia, the American Association of Oral and Maxillofacial Surgeons, American College of Radiology, American Dental Association, American Society of Dentist Anesthesiologists, and Society of Interventional Radiology

Most Cited

ASA Physical Status Classifications: A Study of Consistency of Ratings

STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea

Uptake of Halothane by the Human Body

Email alerts

Article Activity Alert

Online First Alert

Anesthesiology Featured Articles Alert

Close Modal

Related Articles

Complications of Different Ventilation Strategies in Endoscopic Laryngeal Surgery: A 10-year Review

Anesthesiology (January 2006)

Pneumothorax in the Intensive Care Unit: Incidence, Risk Factors, and Outcome

Anesthesiology (January 2006)

High-frequency Ventilation Does Not Provide Mortality Benefit in Comparison with Conventional Lung-protective Ventilation in Acute Respiratory Distress Syndrome: A Meta-analysis of the Randomized Controlled Trials

Anesthesiology (April 2015)

End-tidal to Arterial Gradients and Alveolar Deadspace for Anesthetic Agents

Anesthesiology (September 2020)

The Ventilation-Perfusion Relation and Gas Exchange in Mitral Valve Disease and Coronary Artery Disease Implications for Anesthesia, Extracorporeal Circulation, and Cardiac Surgery

Anesthesiology (April 1997)

Effect of Inverse I : E Ratio Ventilation on Pulmonary Gas Exchange in Acute Respiratory Distress Syndrome (2024)

References

Top Articles
Latest Posts
Article information

Author: Tish Haag

Last Updated:

Views: 5672

Rating: 4.7 / 5 (47 voted)

Reviews: 86% of readers found this page helpful

Author information

Name: Tish Haag

Birthday: 1999-11-18

Address: 30256 Tara Expressway, Kutchburgh, VT 92892-0078

Phone: +4215847628708

Job: Internal Consulting Engineer

Hobby: Roller skating, Roller skating, Kayaking, Flying, Graffiti, Ghost hunting, scrapbook

Introduction: My name is Tish Haag, I am a excited, delightful, curious, beautiful, agreeable, enchanting, fancy person who loves writing and wants to share my knowledge and understanding with you.